Operating Regulations and Steps of Bengbu Ruixiang Fire Truck Pump
2021-08-051. Inspection before starting the fire pump of the fire truck
Read details
1. Check the process valve switching conditions, and whether the corresponding return valve switching conditions meet the requirements.
(1) During the daily test of the pump, the return valve should be fully open and the valve block valve should be in the closed position. When trying 1# foam pump and 2# pump foam outlet, it is necessary to close the three foam tank inlet valves Vp111, Vp112, and Vp212, and open the Px021 return valve to start the pump; try 2# pump water outlet, 3#, 4# fire truck The Px011 return valve must be opened when the fire engine fire pump is used to start the pump. After testing the pump, restore all valves to the specified state.
(2) When there is an emergency or when water is needed for fire fighting drills, open the valve in the valve block corresponding to the position where fire water (foam) is needed, and the return valve is closed.
(3) The inlet valve of the pump must have a normally open, and the outlet valve must be in the closed position.
2. Check that the clutch handle of the vacuum suction device should be in the “closed” position.
3. Open the air release valve and close the air release valve after resetting the float assembly.
2. Operation steps of starting and stopping the fire pump of the fire truck
1. After starting the pump, check the running current of the motor and whether the pump is running normally. If there is any abnormality, stop the pump immediately.
2. Observe the pressure gauge at the outlet of the water pump. When the pointer of the pressure gauge reaches the rated working pressure and is stable, gradually open the outlet valve to try to make the pump work in the rated state.
3. After the pump is normally filled with water, move the clutch handle of the vacuum suction device to the position of “divided”.
4. Observe the pressure of the valve group, the pressure of the clean water valve group is kept at about 0.8Mpa, and the foam valve group is kept at about 1.0Mpa. If the pressure cannot be maintained, the outlet of the pump and the return valve can be adjusted appropriately to control the pressure.
5. The temperature of the pump and motor bearings should be checked frequently. The maximum temperature should not exceed 75 degrees. Check that the working current of the motor should be within the normal range.
6. After stopping the pump, restore all valves to their normal state according to the requirements of the valve opening and closing state diagram.
7. Move the clutch handle of the vacuum suction device to the “close” position, open the bleed valve, reset the float assembly, and be in a state of preparation.
8. If the pump starts, if the pressure reaches 0.8Mpa and then immediately returns to about 0.4Mpa, the water cannot be discharged normally. At this time, stop the pump immediately, open the air release valve to reset the float assembly, and restart.
9. Under normal circumstances, one of the 1# and 2# stabilized pumps is in working condition and the other is in standby condition.
Three, fire truck fire pump maintenance and maintenance
1. Check every shift and ensure that the power supply and circuit of the fire protection system are unobstructed, and the electrical equipment is in good condition.
2. Pump once per shift, the coupling should be uniform in weight, no abnormal noise, and make a record.
3. Check the lubricating oil level in the vacuum suction device on the 5th, 10th, 15th, 20th, 25th, and 30th days of each month, and the refueling position is on the center line of the oil window or slightly below the center line; start the fire engine for fire fighting Car fire pump, check the pump time and make a record, 1#, 2# pumps run for 15 minutes, 3#, 4# pumps run for 5 minutes.
4. After the pump is started, check the operation of the float assembly, and there should be no water in the exhaust hose. If there is water, the float seal must be replaced.
5. After the pump is started, check whether the size and sealing body of the vacuum suction device is tight and whether the exhaust is normal.
6. After the pump is started, check the sealing degree of the packing, and the leakage should not exceed 10-30 drops/min.
7. Regularly check the lubricating oil in each part of the pump to ensure that the lubrication system is working properly.
8. Regularly check whether each connection part is tight and whether it is loose.
Keep the liquid level of fire A and B pools at 3.45m from the bottom of the pool, and build a new 1700m3 fire pool to ensure 70% of the water volume.
1. Inspection before starting the fire pump of the fire truck
1. Check the process valve switching status, and whether the corresponding return valve switching status meets the requirements.
(1) During the daily test of the pump, the return valve should be fully opened and the valve group valve should be in the closed positio -
14 part-time fire brigades in towns and villages in Xinhua, Loudi carry out skills competition
2021-08-05Loudi News Network (Reporter Wu Mingming, Correspondent Peng Weiguo Xie Huifang) In order to prevent fire accidents, strengthen the professional quality of township firefighting teams, and enhance the rapid response ability of part-time firefighting teams in fighting fires and disaster relief, June 4, Loudi City The part-time firefighting team skills contest of Xinhua County kicked off. 14 firefighting teams from across the county participated in this skill contest. The contest included laying and connecting two trays of hoses, motorized pump trains, and water guns.
Read details
“Stay in position, prepare, start……”With the referee’s whistle, the players rushed out of the starting point like an arrow from the string, teammates on the side of the field shouted anxiously, and the players sweated and raced against time. There was a kind of "hot" atmosphere in the whole arena. The competition includes three projects: the water discharge exercise of the motorized pump train, the extension exercise of the hose at the water gun, and the connection of the two trays of the hose. There are sixty-year-old "veterans" and "newborn calves" on the competition field. Recruits”, everyone compares physical fitness, stamina, style, and courage. You chase after me, not to be outdone. The part-time firefighters have a tenacious fighting style and a brave fighting spirit.
It is understood that the participating township and township part-time firefighting teams are composed of 7 members. According to the standard of "one vehicle, one team, one room", they are equipped with fire trucks, fire fighting equipment, and built a special fire fighting garage. , Each team can receive 60,000 yuan of special government funding each year, which fundamentally solves the "worries for the future".
Xinhua County has a wide area and a large population. The 27 towns and towns under its jurisdiction are mostly remote villages. The rural fire protection infrastructure is weak, and various factors that induce rural fires are increasing year by year. Therefore, a township that can fight fires has been established. Part-time firefighting teams can not only effectively alleviate the current situation of insufficient firefighting police force, but also play an important role in safeguarding local economic construction. In recent years, the construction of the team has received strong support from the local county people's government. The Xinhua County Fire Brigade has continuously provided professional technical guidance in terms of fire fighting knowledge training and fire fighting drills.
Through this competition, we comprehensively reviewed the business level of part-time fire brigades in various townships, improved the operational skills and fire fighting skills of part-time firefighters, promoted the construction of part-time firefighters, and created a high-quality, professional Towns and towns with strong fire fighting and rescue capabilities have laid a solid foundation for the "Patron saint". The relevant person in charge stated that currently, 14 part-time teams in towns and villages have been built and put into use, and strive to achieve 100% coverage of part-time teams in towns and villages next year. "Now, even if there is a fire in the most remote township, the part-time firefighting team of the township can rush to the scene for disaster relief as soon as possible. ”(Editor/Liang Xiongjun) -
The tube replacement method for repairing the radiator core tube of Bengbu fire truck
2021-08-05Repair the radiator core tube by looking at the cause of the failure and the corresponding conditions in a targeted manner. In addition to taking over the repair, you can also replace the radiator core tube to ensure the normal operation of the fire truck. When using this method for maintenance, prepare two special tools for resistance heaters and acetylene heaters.
Read details
Your current location: Home >> News >> Company News
The tube replacement method for the repair of the radiator core tube of the fire truck
The repair of the radiator core tube is dealt with according to the cause of the failure and the corresponding conditions. In addition to taking over the repair ceremonies, the radiator core tube can also be replaced to ensure the normal operation of the fire truck. When using this method for maintenance, prepare two special tools for resistance heaters and acetylene heaters.
1. Insert a flat copper strip into the core tube of the radiator that needs to be removed and replaced, and pull it back and forth several times to remove internal scale.
2. Insert the resistance heater into the core tube of the radiator, and connect the voltage of 24V at both ends. After the resistance wire burns red, the solder also melts, and at the same time, the solder at the junction of the radiating pipe and the upper and lower bottom plates is melted with an acetylene flame heater to separate it.
3. Cut off the power supply and use wire cutters to pull out the radiator core tube together with the resistance heater while it is hot.
4. After removing the residue and dirt of the radiator core tube, insert the radiator core tube of the radiator to be replaced with the solder on the surface, then insert the resistance heater and energize, and cut off after the solder on the surface of the radiator core tube is melted The power supply, wait for the temperature to gradually decrease and the welding is firm, and then pull out the resistance heater.
5. Weld the upper and lower plates.
According to the above steps, the tube replacement method can be used to eliminate the damage of the fire truck radiator core tube that affects the normal driving fault. -
Requirements for the setting of fire lanes in buildings
2021-09-06The fire lane is a road for fire trucks to pass through when extinguishing a fire. The purpose of setting up the fire lane is to make the fire trucks reach the fire site smoothly in the event of a fire, and the firefighters quickly carry out the fire fighting, put out the fire in time, and minimize the casualties and fire losses.
Read details -
Fire safety knowledge (3)
2021-09-06Foam fire extinguishers are suitable for extinguishing the initial fires of oil and general substances.
Read details -
Fire safety knowledge (2)
2021-09-06The fire is merciless. In the event of a fire, the students should keep a clear head, race against time, and leave quickly. If you are besieged by fire, you must adapt to the circumstances and try to get out of danger.
Read details -
Fire safety knowledge (1)
2021-09-06Fire is a natural phenomenon. Tamed fire is a friend of mankind. It brings light and warmth to people and promotes the progress of human civilization and society. However, if the fire is out of control and causes a fire, it will cause huge losses to people's lives and property. According to statistics, there were more than 140,000 fires in my country in 1997, with more than 7,000 casualties, and 8% of the fires were caused by children playing with fire. It can be seen how important it is for students to understand and master some fire protection knowledge to reduce and prevent the occurrence of fires.
Read details -
The history of the assault boat
2021-09-06The prototype of the assault boat
Read details
According to the records of Motorboating in the Guinness Book of the World, the history of inflatable boats can be traced back to 880 BC. King Ashurnasirpal II, the Assyrian, ordered his troops to continuously inflate the greased hides so that they could pass the river. ! In ancient China, in the Song and Ming dynasties, people also used sealed and inflated animal skins to pass rivers. The emergence of the assault boat is mainly due to its speed
In 1839, after the Duke of Wellington made the first pontoon test of an inflatable boat, in 1840, the British Thomas Hancock designed an inflatable raft and included his work related introduction in the "British Natural "The Origin and Process of Rubber" in the book. In 1844, a navy captain Halkett designed a wheel-shaped inflatable boat, which was used in Arctic expeditions many times. Frenchman Clement Ader also designed a floating vessel. In fact, many other pioneers invented inflatable rafts, which heralded the birth of "inflatable boats". In 1913, Albert Meyer of Germany came up with a fairly novel design. By 1920, his company, Ginseng Bau Pneum. Boote is marketing his "Qi" ship, 9 of which have been used in the German army, and have gradually become an assault boat
Modern assault boat
In France and the United Kingdom, ZODIAC and RFD successively launched the first modern rubber boats. In 1919, the founder of RFD Ray Foster Dagnall tested an inflatable boat on Lake Wisely in the United Kingdom and improved his design in the 1930s. This is the ancestor of a popular inflatable life raft. In France in 1934, Pierre Debroutelle designed the prototype of an inflatable boat.
The first modern inflatable boat was used in the French Navy. The development model of ZODIAC triggered the rapid development of civilian and military inflatable boat industries. Correspondingly, Pierre Debroutelle designed the first U-shaped rubber boat in 1937. On August 10, 1943, he applied for a patent for this design. This is also the most straightforward version of sports and entertainment inflatable boats to this day.
Assault boat components and structure
Since then many new manufacturers, new models and new designs have been introduced to the market. Inflatable boats are no longer small inflatable boats on the back of a big yacht! It can reach 45 feet long or even longer! The “rigid” glass fiber reinforced plastic hull and aluminum hull have gradually replaced the original inflatable bottom! Luxurious and beautiful decorative parts, even the ship’s warehouse also appeared on the inflatable boat. Corresponding to its name, today, inflatable boats often just refer to the boat’s pontoons being inflated, and the bottom of the boat may be made of fiberglass and aluminum. However, inflatable boats have always existed and changed. More and more popular! -
Recruiting agents from all provinces and regions across the country
2021-09-06Our company is mainly engaged in the production, sales and service of fire trucks and fire fighting equipment; there are more than 10 types of township fire trucks, including a variety of patented fire trucks; and sales of domestic famous brand manufacturers of heavy foam (water tank), emergency rescue Rescue, anti-chemical decontamination fire trucks and personal protective equipment, anti-chemical decontamination, special service equipment, etc.
Read details -
Loudi Xinhua: 6 more township fire brigades were built, and villagers won fire trucks
2021-09-06Recently, Xinhua County, Loudi City, Hunan Province held the 4th batch of township part-time firefighting team license and vehicle issue ceremony. Deputy County Chief and Director of Public Security Bureau Luo Yiqiu; Deputy Director of Public Security Bureau Liu Huaxiang attended the ceremony; the ceremony was organized by the county government Deputy Director Chen Xiguang presided over.
Read details
Contact us
- Service Hotline: 0552-4126680 , 13909628228
- E-mail: Sale:287771992@qq.com
- Address: The north side of the east end of Liupu Road, Wangzhuang Town, Guzhen County, Anhui Province
- Follow Ruixiang
- Mobile
Copyright © 2021 Bengbu Ruixiang Fire Electromechanical Device Co.,ltd. All Rights Reserved 皖ICP备13012958号-1
- Follow Ruixiang
- Mobile